Schneider Automation Interbus Fiber Optic CommunicationsAdapter Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Industrial networking made easy! www.anybus.com
Anybus® is a registered trademark of HMS Industrial Networks AB, Sweden, USA, Germany and other countries. Other marks and words belong to their respecve companies.
All other product or service names menoned in this document are trademarks of their respecve companies.
Part No: MMA201 Version 1 09/2011 - © HMS Industrial Networks - All rights reserved - HMS reserves the right to make modicaons without prior noce.
Technical Details Standard
Weight 500 g, 1,100 lb
Dimensions (L•W•H) 126•110•42 mm, 4,96•4,33•1,65”
Protection class IP20, NEMA rating 1
Enclosure material Aluminium
Installation position Any
Mounting DIN rail (35•7,5/15) EN 50022
Certications
UL File number: E203225 UL 508 Ind. Cont. Eq.
Hazardous Locations CLASS 1, DIVISION 2, GROUPS A, B, C AND D, T4 ANSI/ISA 12.12.01-2000
ATEX Zone 2, Cat 2 EN60079-15
EN60079-11
CE 2004/108/EC EN61000-6-4
EN61000-6-2
Electrical Characteristics
Power 24 VDC +/- 10 %
Current consumption Max 300 mA, Typical 200 mA
Hardware Characteristics
Reverse voltage protection Yes
Short circuit protection Yes
Environmental Characteristics
Operating temp 0 to 65
o
C, 32 to 149
o
F IEC 68-2-1, IEC 68-2-2
Storage temp -40 to 85
o
C, -40 to 185
o
F IEC 68-2-1, IEC 68-2-2
Relative Humidity 5-95 % non condensing IEC 68-2-30
Installation altitude Up to 2 000 m
Immunity and Emission for Industrial Environment
Electrostatic discharge +/- 4 kV EN 61000-4-2
Electromagnetic RF elds 10 V/m 80 MHz - 1 GHz
3 V/m 1,4 GHz - 2,0 GHz
1 V/m 2,0 GHz - 2,7 GHz
EN 61000-4-3
Fast Transients +/- 1 kV EN 61000-4-4
Surge protection +/- 1 kV EN 61000-4-5
RF conducted interference 10 V/rms EN 61000-4-6
Emission (at 10 m) 40 dB 30 MHz - 230 MHz
47 dB 30 MHz - 1 GHz
EN 55016-2-3
Single Pack Accessories
• Resource CD • Conguration Cable (RS232) com Port • Installation sheet
TECHNICAL SPECIFICATIONS
HMS Industrial Networks - Worldwide
HMS - Sweden (HQ)
Tel : +46 (0)35 17 29 00 (Halmstad HQ)
Tel: + 46 (0)35 17 29 24 (Västerås ofce)
E-mail: sales@hms-networks.com
HMS - China
Tel : +86 (0)10 8532 3183
E-mail: cn-sales@hms-networks.com
HMS - Denmark
Tel: +45 35 38 29 00
HMS - France
Tel: +33 (0)368 368 034
HMS - Germany
Tel: +49 (721) 989 777-000
E-mail: ge-sales@hms-networks.com
HMS - India
Tel: +91 20 40111201
E-mail: in-sales@hms-networks.com
HMS - Italy
Tel : +39 039 59662 27
HMS - Japan
Tel: +81 (0)45 478 5340
E-mail: jp-sales@hms-networks.com
HMS - UK
Tel: +44 (0) 1926 405599
HMS - United States
Tel: +1 312 829 0601
E-mail: us-sales@hms-networks.com
NETWORK SPECIFIC FEATURES
1 = Network connector, 2 = Baud rate,
3 = I/O data, 4 = Other, 5 = Amount of slaves / adapters
MASTER
ASI
1 = 2*2p; 5,08 Phoenix Plug 2 = 167 kbit/s 3 = 248/186 (digital input/output)
4 = ASI version 3.0 5 = 62
DeviceNet
1 = 5*5p; 5.08 Phoenix Plug 2 = 125-500 kbit/s
3 = 512 byte IN/OUT 4 = DeviceNet 2.0 scanner 5 = 63
EtherNet/IP
1 = RJ45 2 = 10/100 Mbit/s 3 = 509/505 IN/OUT
4 = FTP Server, Web Server, SMTP Client 5 = 64
Probus
1 = DSUB9F 2 = Up to 12 Mb
3 = 512 IN/OUT 4 = Probus DP (IEC 61158) 5 = 125
SLAVE
CANopen
1 = DSUB9M 2 = Up to 1 Mbit/s
3 = 512 byte IN/OUT 4 = Supports prole CIA DS301 V4.02
CC-Link
1 = 1*5p; 5.08 Phoenix Plug 2 = Up to 10 Mbit/s
3 = 896 IO points, 128 word IN/OUT 4 = Up to 4 occupied stations
ControlNet
1 = 2*BNC Coax + RJ45 (NAP) 2 = 5 Mbit/s
3 = 450 byte IN/OUT 4 = Communications adapter, prole n. 12
DeviceNet
1 = 1*5p; 5.08 Phoenix Plug 2 = 125-500 kbit/s
3 = 512 byte IN/OUT 4 = Communications adapter, prole n. 12
EtherCAT
1 = 2*RJ45 2 = 100 Mbit/s
3 = 512 byte IN/OUT 4 = DS301 V4.02 compliant, 4 FMMU Channels
EtherNet/IP
1 = RJ45 2 = 10/100 Mbit/s 3 = 509/505 IN/OUT
4 = EtherNet/IP group 2 and 3 server. Modbus TCP slave functionality
FIPIO
1 = DSUB9M 2 = 1 Mbit/s 3 = 32 words IN/OUT
4 = Data exchange according to FIPIO Extended Device Prole, Class 0
Interbus
RS485
1 = DSUB9F + DSUB9M 2 = 500 kbit/s, 2 Mbit/s
3 = 20 byte IN/OUT (process data), 512 bytes IN/OUT (with PCP)
4 = PCP V.2.0 (0 or 1 word)
Interbus Fibre
Optic
1 = HFBR-2505C, HFBR-1505C 2 = 500 kbit/s, 2 Mbit/s
3 = 20 byte IN/OUT (process data), 512 bytes IN/OUT (with PCP)
4 = IEC874-2 and DIN47258
J1939
1 = 1*5p; 5.08 Phoenix Plug (Probus / EtherNet/IP / Modbus-TCP) DSUB15M
(Modbus RTU) 2 = - 3 = 2048 bytes IN/OUT (Modbus RTU), 248-500
(EtherNet/IP), Modbus TCP 499/495 bytes Probus 4 = SAEJ1939
LONworks
1 = 1*5p,08 Phoenix Plug 2 = 78 kbit/s 3 = 256 network variables in/out
4 = Lonmark objects handling
Modbus Plus
1 = DSUB9F 2 = 1 Mbit/s 3 = 32 words IN/OUT (global data)
4 = Modbus Plus Host Firmware Rev. 77
Modbus RTU
1 = DSUB9F 2 = 1,2-57,6 kbit/s 3 = 256 registers in each direction
4 = RS232 and RS485
Modbus TCP
1 = RJ45 2 = 10/100 Mbit/s 3 = 512 byte IN/OUT 4 = Supports EtherNet/IP
Probus
1 = DSUB9F 2 = Up to 12 Mbit/s
3 = 244 IN/OUT (416 total) 4 = Probus DP (IEC 61158)
Pronet-IO
1 = RJ45 2 = 10/100 Mbit/s 3 = 512 byte IN/OUT
4 = RT Communication and Cyclic data exchange
Pronet IRT
1 = 2*RJ45 2 = 100 Mbit/s 3 = 220 byte IN/OUT
4 = RT Communication and integrated
LED indicators
DIN-rail mounting
DSUB-9M conguration
connector
Rugged aluminium housing
24 VDC power supply
2-pole Phoenix plug
Network connector 1
Network connector 2
Vista de pagina 14