www.anybus.com www.anybus.com
8 9
Anybus Communicator RTU
Features and benets
When converng the Modbus RTU protocol, the Communicator
acts as Master on the serial network
Predened 6-step Modbus RTU conguraon wizard
Enables any automaon device with a serial RS-232/422/485
Modbus RTU Slave interface to parcipate on a network
No hardware or soware changes are required for the connected
automaon device
Compable with all Allen Bradley and Guard PLCs
Complete protocol conversion performed by the Communicator,
no PLC funcon blocks required
Save/Load funcon means a completed conguraon can be reused
for many other installaons
CE,
C
UL
US
and HazLoc cercaons
Global free technical support and consultancy
Conguraon video available on www.anybus.com
Anybus
®
Communicator™ - Protocol converter gateways
Proven and trusted
The Anybus Communicator has been
safely connecng devices to Rockwell
Automaon networks and systems for
over 10 years.
Its exibility means that it is used in
a wide variety of industries such as
factory automaon, mining, waste
water management, Infrastructure
Building and HVAC and many more.
With the Anybus Communicator,
your devices are connected fast. Its
unrivalled performance, exibility and
reliability gives you the
peace of mind you
need when solving
your connecvity
problems.
Niklas Selander
Product Manager -
Anybus
Gateways
Order information
Network: PartNo:
ControlNet AB7006
DeviceNet AB7001
EtherNet/IP 2-port AB7072
*See page 53 for mechanical and technical
specicaons
Optional accessories
USB-RS232 conguraon adapter
Part No: 019570
Converting from Modbus RTU protocols to
ControlNet, DeviceNet and EtherNet/IP
Anybus
®
Communicator™ - Protocol converter gateways
Anybus Communicator DF1
Converting from DF1 protocols to ControlNet,
DeviceNet and EtherNet/IP
The Communicator DF1 is used to enable non-networked
automaon devices to parcipate on DeviceNet,
ControlNet and EtherNet/IP.
With its selectable serial RS-232/422/485 interface, the
Communicator converts the DF1 protocol and enables
devices such as Rockwell Automaon/Allen Bradley PLC-5
and SLC-500 among others, to parcipate on the network
without the need for extensive PLC funcon blocks.
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
When to use
Integrates non-networked devices
and machines with a serial
RS-232/422/485 interface to a
DeviceNet/ControlNet or
EtherNet/IP PLC control system.
Conguration
As the most common serial
Modbus RTU interface is used,
HMS takes away the hassle
of scripng and serial frame-
building by using an easy 6-step
visual conguraon wizard that
contains predened Modbus RTU
commands.
ControlNet
1 = 2*BNC Coax + RJ45 (NAP)
2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, prole
n. 12
DeviceNet
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Communications adapter, prole
n. 12
EtherNet/IP
2-port
1 = 2*RJ45 2 = 10/100 Mbit/s
3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3 server
APPLICATION EXAMPLE SINGLE-DROP APPLICATION EXAMPLE MULTI-DROP
CompactLogix
DeviceNet Network
Communicator RTU
DeviceNet
Modbus RTU
via RS-232
Example: Kinec 3 servo drive with
a serial Modbus RTU interface
ControlLogix
EtherNet/IP Network
Communicator RTU
EtherNet/IP
Modbus RTU via RS-485/422
Example: Connects up to 31 PF4 drives via RS-485
APPLICATION EXAMPLE SINGLE-DROP APPLICATION EXAMPLE MULTI-DROP
Communicator
EtherNet/IP
DF1 via RS-232
Example: Allen Bradley SLC500
with a serial DF1 interface
ControlNet Network
Communicator
ControlNet
DF1 RS-485/422
Example: Connecng PLC5s via RS-485
Features and benets
When converng the DF1 protocol the Communicator acts as a
DF1 Half Duplex Master on the serial network
Enables any automaon device with a serial RS-232/422/485 DF1
interface to parcipate on a network
No hardware or soware changes are required for the connected
automaon device
Compable with all Allen Bradley and Guard PLCs
Complete protocol conversion performed by the Communicator,
no PLC funcon blocks required
Save/Load funcon means a completed conguraon can be reused
for many other installaons
CE,
C
UL
US
and HazLoc cercaons
Global free technical support and consultancy
Conguraon video available on www.anybus.com
When to use
Integrates non-networked devices
and machines with a serial
RS-232/422/485 interface to a
DeviceNet/ControlNet or
EtherNet/IP PLC control system.
HMS takes away the hassle
of scripng and serial frame
building by using an easy visual
conguraon that allows for the
easy generaon of DF1 scan lists.
Tech tip
Using the Communicator to
connect to serial devices
eliminates the need for a serial
opon card and the need for
complex funcon block
programming.
Furthermore, as the
Communicator is not restricted
to the length of a serial cable, it
can be installed almost anywhere
within the installaon.
With its intelligent internal data
mapping system, the
Communicator enables even very
slow devices to parcipate on the
network without any performance
restricons.
Using the Rockwell Automaon Integrated Architecture
Builder (IAB), engineers can integrate the Communicator
making it easy to include in your network system design.
ControlLogix
Order information
Network: PartNo:
ControlNet AB7006
DeviceNet AB7001
EtherNet/IP 2-port AB7072
*See page 53 for mechanical and technical
specicaons
Optional accessories
USB-RS232 conguraon adapter
Part No: 019570
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
ControlNet
1 = 2*BNC Coax + RJ45 (NAP)
2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, prole n. 12
DeviceNet
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Communications adapter,
prole n. 12
EtherNet/IP
2-port
1 = 2*RJ45 2 = 10/100 Mbit/s
3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3 server
EtherNet/IP Network
CompactLogix
With the Anybus Communicator RTU you can connect a non-
networked device to any major eldbus or industrial Ethernet
network. The Communicator handles the complete Modbus
RTU serial protocol without the need for extensive PLC
funcon blocks.
The Communicator RTU has a selectable serial RS-232/422/485
interface making it possible to connect one or mulple devices
using just one Communicator. This compact gateway
consumes very lile space in a cabinet and is easily
mounted on a standard DIN rail.
PROTOCOL CONVERTER GATEWAYS
Using the Rockwell Automaon Integrated Architecture
Builder (IAB), engineers can integrate the Communicator
making it easy to include in your network system design.