Schneider Automation Interbus Fiber Optic CommunicationsAdapter Información técnica Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
www.anybus.com www.anybus.com
16 17
ControlNet
1 = 2*BNC Coax + RJ45 (NAP)
2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter,
prole n.12
DeviceNet
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O
EtherNet/IP
1 = RJ45 2 = 10/100 Mbit/s
3 = 512 byte IN/OUT
4 = EIP group 2, DLR support
*See page 53 for mechanical and technical
specicaons
Anybus
®
X-gateway™ - Network to network gateways
Anybus
®
X-gateway™ - Network to network gateways
Anybus X-gateway CANopen Slave to
ControlNet, DeviceNet and EtherNet/IP
This Anybus X-gateway is a bridge between a CANopen network and
a Rockwell Automaon PLC system with ControlNet, DeviceNet or
EtherNet/IP.
The X-gateway copies cyclic I/O data in both direcons enabling data
exchange between networks. This ensures a consistent informaon ow
throughout the enre plant.
Connecting a CANopen network to a Rockwell
Automation PLC system
When to use
Integrang Rockwell Automaon
devices and PLC systems to
CANopen installaons.
Conguration
The included Anybus Conguraon
Manager X-gateway allows you to
dene the I/O data sizes on each
network side and to dene the data
mapping and separaon between
cyclic I/O data and parameter data.
Order information
Network: Part No:
ControlNet AB7868
DeviceNet AB7859
EtherNet/IP AB7838
Optional accessories
USB-RS232 conguraon adapter
Part No: 019570
The X-gateway consists of two communicaon interfaces. The rst
interface provides CANopen Slave funconality. The second interface
provides ControlNet, DeviceNet or EtherNet/IP Adapter funconality.
An easy way to transmit I/O data between a CANopen
network and ControlNet, DeviceNet or EtherNet/IP
Allows for cyclic I/O data exchange between networks
Fast I/O data transfer with average ming between
networks: 10-15 ms
CANopen PDO and SDO data objects supported
Oponal control and status informaon added to the I/O data for
diagnosc purposes
Included Anybus OPC server for extended funconality available
with the EtherNet/IP version
EtherNet/IP version with IT funcons such as dynamic web
server, supporng downloadable customer specic web pages
Robust stand-alone metal housing with CE and
C
UL
US
cercaons
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
CANopen
1 = DSUB9M
2 = 10 Kbits to 1 Mbit/s,
3 = 512 bytes IN/OUT
4 = Supports prole CIA DS301
V4.02
ControlNet
1 = 2*BNC Coax + RJ45 (NAP)
2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, prole
n.12
DeviceNet
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O
EtherNet/IP
1 = RJ45 2 = 10/100 Mbit/s
3 = 512 byte IN/OUT
4 = EIP group 2, DLR support
*See page 53 for mechanical and technical
specicaons
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
Anybus X-gateway CC-Link Slave to
ControlNet, DeviceNet and EtherNet/IP
This Anybus X-gateway is a bridge between a CC-Link network and
a Rockwell Automaon PLC system with ControlNet, DeviceNet or
EtherNet/IP.
The X-gateway copies cyclic I/O data in both direcons enabling data
exchange between networks. This ensures a consistent informaon ow
throughout the enre plant.
Connecting a CC-Link network to a Rockwell
Automation PLC system
When to use
Integrang Rockwell Automaon
devices and PLC systems to CC-Link
installaons.
Conguration
The included Anybus Congura-
on Manager X-gateway allows
you to dene the I/O data sizes on
each network side and to dene
the data mapping and separa-
on between cyclic I/O data and
parameter data.
Order information
Network: Part No:
ControlNet AB7871
DeviceNet AB7862
EtherNet/IP AB7841
Optional accessories
USB-RS232 conguraon adapter
Part No: 019570
EtherNet/IP Network
FMCG equipment (slaves) on a CC-Link Network
Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CC-Link Slave
ControlLogix PLC
EtherNet/IP Scanner
PLC
CC-Link Master
The X-gateway consists of two communicaon interfaces. The rst
interface provides CC-Link Slave funconality. The second interface
provides ControlNet, DeviceNet or EtherNet/IP Adapter funconality.
An easy way to transmit I/O data between a CC-Link
network and ControlNet, DeviceNet or EtherNet/IP
Allows for cyclic I/O data exchange between networks
Fast I/O data transfer with average ming between
networks: 10-15 ms
Oponal control and status informaon added to the I/O data for
diagnosc purposes
Uses the CC-Link PLC prole for data exchange
Included Anybus OPC server for extended funconality available
with the EtherNet/IP version
EtherNet/IP version with IT funcons such as dynamic web
server, supporng downloadable customer specic web pages
Robust stand-alone metal housing with CE and
C
UL
US
cercaons
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
CC-Link
1 = DSUB9 Female
2 = 156 kbps to 10 Mbit/s,
3 = Ver 1: 128 I/O points, 16 words
IN/OUT
4 = Ver 2.0: 896 I/O points, 128
words IN/OUT
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
EtherNet/IP Network
Slaves on a CANopen Network
Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CANopen Slave
MicroLogix PLC
EtherNet/IP Scanner
PLC
CANopen Master
NETWORK TO NETWORK GATEWAYS
Using the Rockwell Automaon Integrated Architecture
Builder (IAB), engineers can integrate the X-gateway making
it easy to include in your network system design.
Using the Rockwell Automaon Integrated Architecture Builder
(IAB), engineers can integrate the X-gateway making it easy to
include in your network system design.